Revision 1

#29964Store at +4C

Cell Signaling Technology

Orders: 877-616-CELL (2355) [email protected]

Support: 877-678-TECH (8324)

Web: [email protected] cellsignal.com

3 Trask LaneDanversMassachusetts01923USA
For Research Use Only. Not for Use in Diagnostic Procedures.
:

:

:

:

Product Information

Product Usage Information

Prior to use, allow the beads to equilibrate to room temperature for at least 15 minutes. From the CellSimple Cell Analyzer main screen, choose the Open Flow Cytometry application and select both detection channels PMT1 (525/45 nm) and PMT2 (561 nm LP). The fluorescent gain setting should be set to “default”. Immediately prior to loading the Performance Beads, vortex them on high for 15 seconds then pipette 75 μl into the cassette and analyze. Do not dilute the aqueous solution. Gate the bead populations according to MFI and diameter (μm). Please see the CellSimple User Guide for more details about using the Open Flow Cytometry Application.

Storage

Store at 4° C and protect from light. Do not freeze as this will compromise bead performance. The Performance Beads are stable for at least 12 months when stored at the recommended conditions.

Product Description

CellSimple Performance Beads are available as a quality control reagent for use with the CellSimple Cell Analyzer. The reagent contains a mixture of four beads: smaller red and larger green fluorescent beads, each with size-matched non-fluorescent beads. The four-bead mixture is run simultaneously and gated to determine fluorescence intensity, diameter and total count. The Performance Beads can be used on a regular basis to check instrument performance and reproducibility. Example data are shown in the attached figures.

Background

The CellSimple Cell Analyzer is a benchtop instrument that utilizes a disposable thin-film cassette and a combination of a 488 nm laser, two photomultiplier tubes (525/45 nm and 561 nm LP filters), Coulter Principle-based cell measurements, and on-board software to provide easy-to-run applications and data analysis. Data acquisition occurs within approximately 10 seconds per test. The instrument relies on disposable cassettes for sample handling, which alleviates the need for flow cell cleaning and fluidics maintenance and the instrument is small enough to be portable between the lab bench and the hood. Applications include quantitative assessments of cell viability, apoptosis, other labeled antibody markers and single and multiplexed bead-based assays for protein and cellular analysis.

Species Reactivity

Species reactivity is determined by testing in at least one approved application (e.g., western blot).

Cross-Reactivity Key

H: human M: mouse R: rat Hm: hamster Mk: monkey Vir: virus Mi: mink C: chicken Dm: D. melanogaster X: Xenopus Z: zebrafish B: bovine Dg: dog Pg: pig Sc: S. cerevisiae Ce: C. elegans Hr: horse GP: Guinea Pig Rab: rabbit All: all species expected

Trademarks and Patents

Cell Signaling Technology is a trademark of Cell Signaling Technology, Inc.
All other trademarks are the property of their respective owners. Visit cellsignal.com/trademarks for more information.

限制使用

除非 CST 的合法授书代表以书面形式书行明确同意,否书以下条款适用于 CST、其关书方或分书商提供的书品。 任何书充本条款或与本条款不同的客书条款和条件,除非书 CST 的合法授书代表以书面形式书独接受, 否书均被拒书,并且无效。

专品专有“专供研究使用”的专专或专似的专专声明, 且未专得美国食品和专品管理局或其他外国或国内专管机专专专任何用途的批准、准专或专可。客专不得将任何专品用于任何专断或治专目的, 或以任何不符合专专声明的方式使用专品。CST 专售或专可的专品提供专作专最专用专的客专,且专用于研专用途。将专品用于专断、专防或治专目的, 或专专售(专独或作专专成)或其他商专目的而专专专品,均需要 CST 的专独专可。客专:(a) 不得专独或与其他材料专合向任何第三方出售、专可、 出借、捐专或以其他方式专专或提供任何专品,或使用专品制造任何商专专品,(b) 不得复制、修改、逆向工程、反专专、 反专专专品或以其他方式专专专专专品的基专专专或技专,或使用专品开专任何与 CST 的专品或服专专争的专品或服专, (c) 不得更改或专除专品上的任何商专、商品名称、徽专、专利或版专声明或专专,(d) 只能根据 CST 的专品专售条款和任何适用文档使用专品, (e) 专遵守客专与专品一起使用的任何第三方专品或服专的任何专可、服专条款或专似专专

Revision 1
#29964

CellSimple Performance beads

CellSimple™ Performance beads: Image 1 Expand Image
CellSimple Performance Beads were analyzed using the Open Flow Cytometry Application detecting in both green (525/45nm, left panel) and red (561nm LP, right panel) channels. 非荧光和荧光微珠根据中位荧光强度 (MFI) 和直径 (μm) 设置门控。结果如点阵图下方的黑色长方形框所示。仪器屏幕截图如图所示。